4.11 USER FUNCTIONS

This mode provides you with a gateway to the user functions
through the regular user programming menu. You may:
• Program the 4 (private) telephone numbers
• Program user codes
• Enroll keyfobs
• Enroll proximity tags
• Select the voice option
• Set the auto arm option
• Set arming time
• Set the squawk option

4.12 RETRIEVING FACTORY DEFAULTS

If you want to reset the PowerMaxComplete parameters to the
factory default parameters, you should enter the installer
menu and perform the "FACTORY DEFLT" function, as
described in the right side illustration. To get the relevant
parameters defaults, contact the PowerMaxComplete dealer.
Note: For PowerMaxComplete with 2 installer codes,
INSTALLER code and MASTER INSTALLER code, only the
master installer code enables to perform factory default function.

4.13 SERIAL NUMBER

The menu "13. SERIAL NUMBER" enables reading the
system serial number for support purposes only.

4.14 CALLING UPLOAD/DOWNLOAD SERVER

Note:
This option is only used during the installation of panels
monitored by compatible central stations.
READY 00:00
NORMAL MODE
USER SETTINGS
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM
6. DEFINE GSM
8. DEFINE OUTPUTS
9. DEFINE VOICE
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT
26
Displayed during
dialing process
Displayed during
download process
Download
Displayed for half
a minute approx.
accompanied by happy
(success) melody
Figure 4.14 – Start UL/DL
• Set the system time and time format
• Set the date and date format
• Set the time scheduler
Refer to the User Guide for detailed procedures.
Caution! If after having programmed the user codes the
system does not recognize your installer code, this
indicates you must have programmed a user code that is
identical with your installer code. If so, access the user
menu and change the code that is identical with your
installer code. This will re-validate your installer code.
Entering to/exit from the FACTORY
DEFLT menu is shown in figure 4.1a
This is a brief display after which all
the factory defaults are retrieved.
This option allows the installer to initiate a call to the
upload/download
PowerMaxComplete configuration to its data base and can
unload predefined parameters to the PowerMaxComplete .
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
COMMUNICATING
Dialing
OK
DOWNLOADING
OK
DOWNLOAD OK
DOWNLOAD FAILED
12. FACTORY DEFLT
server.
The
server
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
TEL # NOT DEFINED
accompanied by sad
Dialing
failed
DIAL ATTEMPT FAIL
accompanied by sad
Download
failed
accompanied by sad
<OK> to restore
ENTER CODE:
[installer code]
PLEASE WAIT ...
uploads
the
Displayed for half
a minute approx.
(failure) melody
Displayed for half
a minute approx.
(failure) melody
Displayed for half
a minute approx.
(failure) melody