WL SENSORS TEST
DIAG. TESTING
(Perform walk test)
Example
BATHROOM
of test
result
Z19 STRONG
display
DIAG. TESTING
Example
FRONT DOOR
of test
(alternating for 5 sec.)
result
display
Z1 POOR
Example
LIVING ROOM
of test
(alternating for 5 sec.)
result
display
Z2 OK
(Each time the OK button is pressed,
the next test result is displayed)

4.11 USER FUNCTIONS

This mode provides you with a gateway to the user
functions through the regular user programming menu. You
may:
• Program the 4 (private) telephone numbers
• Program user codes
• Enroll keyfobs
• Set the auto arm option
• Set arming time
• Set the squawk option

4.12 RETRIEVING FACTORY DEFAULTS

If you want to reset the PowerMaxExpress parameters to the
factory default parameters, you should enter the installer
menu and perform the "FACTORY DEFLT" function, as
described in the right side illustration. To get the relevant
parameters defaults, contact the PowerMaxExpress dealer.
Note: For PowerMaxExpress with 2 installer codes,
INSTALLER code and MASTER INSTALLER code, only
the master installer code enables to perform factory default
function.

4.13 SERIAL NUMBER

The menu "13. SERIAL NUMBER" enables reading the
system serial number and panel ID for support purposes only.

4.14 CALLING UPLOAD/DOWNLOAD SERVER

Note:
This option is only used during the installation of panels
monitored by compatible central stations.
D-302017
NON-PARTITIONING ONLY
WL SIRENS TEST
S1
CPU
WAIT
S1
CPU=STRONG
S2
CPU
PLEASE WAIT...
S2
CPU=STRONG
Note
STRONG/GOOD/POOR/
"NOT OK" (with siren No.,
S1 or S2 before) is
displayed according to the
wireless siren signal
strength).
S1=siren 1. S2 = siren 2.
CPU = Control Panel Unit
= 2 way comm.
Figure 4.10 - Diagnostic Test Flow Chart
(see figure 4.1a)
10. DIAGNOSTICS
WL KEYPADS TEST
K1
CPU
WAIT
K1
CPU=STRONG
K2
CPU
PLEASE WAIT...
K2
CPU=STRONG
Note
STRONG/GOOD/POOR/
"NOT OK" (with keypad
No., K1 or K2 before) is
displayed according to the
wireless siren signal
strength).
K1=keypad1 K2=keypad2
CPU = Control Panel Unit
= 2 way comm.
• Set the system time and time format
• Set the date and date format
Refer to the User Guide for detailed procedures.
Caution! If after having programmed the user codes the
system does not recognize your installer code, this
indicates you must have programmed a user code that is
identical with your installer code. If so, access the user
menu and change the code that is identical with your
installer code. This will re-validate your installer code.
Entering to/exit from the FACTORY
DEFLT menu is shown in figure 4.1a
This is a brief display after which all
the factory defaults are retrieved.
Panel ID is a unique number of the control panel that is used
for registering the PowerMaxExpress to VDNS when using
GPRS.
This option allows the installer to initiate a call to the
upload/download
PowerMaxExpress configuration to its data base and can
unload predefined parameters to the PowerMaxExpress .
GPRS CONN. TEST
( )
*
PLEASE WAIT...
UNIT IS OK
( )
When the OK button is pressed, the test result takes
*
between 15 sec. to 4 mins. before it is displayed,
depe nding on the severity of th e failur e.
See par. 4.10 for a complete list of possible
GSM/GPRS messages.
server.
The
server
LAN CONNECT. TEST
( )
*
PLEASE WAIT...
UNIT IS OK
12. FACTORY DEFLT
<OK> to restore
ENTER CODE:
[installer code]
PLEASE WAIT ...
uploads
the
25