Visonic PowerMaster-10 Installer's Manual page 81

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

07:RPT CNFM ALRM
08:ENTRY DELAY 1
09:ENTRY DELAY 2
DD243 Setup
13:OPERATION MOD
Enter the "03:DD243 SETUP" menu, and press
Option
01:DISARM OPTION
02:ENTRY ALARM
03:END EXIT MODE
04:FOB/KP PANIC
1
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)
4
Define whether the system will report a confirmed alarm.
enable + bypass (default) - The system will report a confirmed alarm and will bypass all
alarmed open zones when the siren ends or when the confirmation timer expires.
disable - The system will not report a confirmed alarm.
enable - The system will report a confirmed alarm.
Two different entry delays allow the user to enter the protected site (while the system is in the
armed state) via 2 specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-
rate warning beeps start sounding once the door is opened, until the last 10 seconds of the
delay, during which the beeping rate increases. Locations No. 1 (entry delay 1) and 2 (entry
delay 2) allow you to program the length of these delays.
Options: 10/15/30 (ENTRY DELAY 1 default)/45/60 (ENTRY DELAY 2 default) seconds;
3/4 minutes
⋅ ⋅ ⋅
03:DD243 SETUP
Configuration Instructions
Define when it is possible to disarm the system:
entry/wl+awy kp – By the control panel when the system is armed AWAY. By keyfob or
keyprox during entry delay only.
entry/all devs - During entry delay, when the system is armed AWAY, by all devices. When
not in entry delay by keyfob or keyprox only.
entry/DD devs (default) - During entry delay, when the system is armed AWAY, by using the
keyfob or keyprox. Keypads cannot disarm at all.
anytime/all dev – At any time and by all devices.
Define whether the system will report a confirmed alarm during an entry delay (see CONFIRM
ALARM below).
DD243 (default) - An alarm initiated by another detector during the entry delay is not regarded
as a confirmed alarm.
EN standard - The control panel will report a confirmed alarm for the second alarm that is
triggered from a different zone within the confirmation time. There are no alarm restrictions
during entry delay or for the delay zone.
Define how the exit delay is terminated or restarted according to the following options:
door/fob only - When the door is closed, or by pressing the AUX button on the keyfob
whichever first.
restart>reentry - Exit delay restarts when the door is reopened during exit delay. The restart
occurs once only. Restarting the exit delay is helpful if the user re-enters immediately after
going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the keyfob
the exit delay has expired, whichever first.
fob/timer (default) - By pressing the AUX button on the keyfob
expired, whichever first.
Define the devices that cannot trigger a panic alarm.
DD243 – MCT-234.
all - All devices can trigger a panic alarm
to configure DD243 compliance standard settings.
D-304271 PowerMaster-10/30 G2 Addendum
1
, or when
1
, or when the exit delay has
1
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents