Figure 35: Leaf Board Numbering

1.10.2.1 Extracting a Leaf Board
Each leaf board has a ejector handle that locks the board in place and serves as a lever for
seating or extracting (see Figure 36).
1. Run the shut down command
For example to shut
"no power enable <module>".
down leaf 16 run the command below.
switch [master] (config) # no power enable L16
2. Disconnect all cables connected to the leaf.
3. Push the ejector handle to unlock the ejector from the chassis.
4. Open the ejector until it is 45 degrees from the leaf.

Figure 36: Ejector Handle

Pull the leaf out of the chassis