Leaf Boards; Figure 35: Leaf Board Numbering - Mellanox Technologies MIS5300 Hardware Installation Manual

324-port infiniband qdr switchx switch platform
Table of Contents

Advertisement

InfiniBand Switch Platform Hardware User Manual
1.9.2

Leaf Boards

The leaf boards are numbered from top to bottom, with corresponding numbers dis-
played to the outside of the leafs vertically along the side panel.
1.9.2.1 Extracting a Leaf Board
Each leaf board has a ejector handle that locks the board in place and serves as a lever for
seating or extracting (see Figure 36).
1. Run the shut down command
down leaf 16 run the command below.
switch [master] (config) # no power enable L16
2. Disconnect all cables connected to the leaf.
3. Push the ejector handle to unlock the ejector from the chassis.
4. Open the ejector until it is 45 degrees from the leaf.
Mellanox Technologies
Do NOT mix replacement parts based on different generations of chip.
Do not install InfiniScale IV based replacement parts within a SwitchX® based chas-
sis and vice versa. All Replacement modules must be consistent with the Chassis fam-
ily and switch chip generation.
When hot-swapping any of the units, it is necessary to wait 1 minute after removing
the defective part before inserting the new part. This is necessary so that the manage-
ment module will start a new cycle checking through the leafs and spines for the FW
versions.

Figure 35: Leaf Board Numbering

"no power enable <module>".
For example to shut
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

Switchx is5300 gt series

Table of Contents