Mellanox Technologies MSX6512-4R Hardware User Manual (129 pages)
216-Port InfiniBand FDR SwitchX Switch Platform
Brand:
Mellanox Technologies
| Category:
Network Router
| Size: 3 MB
Table of Contents
Table of Contents
3
Revision History
9
Table 1: Revision History of this User's Manual
9
About this Manual
10
Intended Audience
10
Related Documentation
10
Table 2: Reference Documents and Websites
10
Mellanox Part Numbering Legend
11
Chapter 1 Overview
12
Product Information
12
Serial Number and Product Version Information
12
Figure 1: Product Label
12
Management Module MAC
13
Product Physical Specifications and Power
13
Figure 2: Product Label Tab Location
13
Figure 3: Management Module MAC Address Location
13
Figure 4: SX6512 Switch Views
14
Features List
15
Infiniband FDR and FDR10 Overview
15
Power Supply Redundancy
15
1000W Power Supply Units
16
Table 3: Opns for Power Supply Units
17
Chapter 2 Installation
18
Installation Safety Warnings
18
Environmental and Safety Recommendations
22
Chassis Package Contents
23
Leaf Package Contents
24
Spine Package Contents
24
Management Package Contents
24
Physical Installation
24
ESD Connection
25
Figure 5: Shelf Installation Kit Parts
26
Figure 6: Chassis Installation Parts
27
Figure 7: Shock Stickers
28
Figure 8: Tilt Sticker
28
Figure 9: Opening the Container
29
Figure 10: Placement of Chassis in Rack
30
Figure 11: Inserting the Caged Nuts for the Shelf
30
Figure 12: Connect Rail Slide to Rack Vertical Support
31
Figure 13: Inserting the Caged Nuts for the Faceplate
31
Figure 14: Chassis on Shelf with Filler Panel
32
Installing the Cable Holder
33
Figure 15: Cable Holders
33
Figure 16: Cable Holder Placement
34
Installing the Chassis
35
Figure 17: Chassis Rails and Rail Slides
35
Figure 18: Installing the Handles
36
Figure 19: Screw the Handles Onto the Chassis
36
Figure 20: the Rails Are Already Connected Onto the Chassis
37
Figure 21: Raising the Chassis Using a Mechanical Lift
38
Figure 22: Put on the Rail Slide
38
Figure 23: SX6512 Chassis on the Shelf
39
Figure 24: Face Plate Mounting Bolt Locations
39
Ground Connections
40
Figure 25: Ground Connection
40
Power Connections
41
Powering up the Switch Platform
41
Figure 26: Multiple Power Inlets - Electric Caution Notification
41
Infiniband QSFP Cable Installation
42
Figure 27: Spine Module
42
Cable Power Classes
43
Supported Approved Cables
43
Hot Swap Insertion and Extraction
43
2.10.1 Power Supply Units
44
Figure 28: Power Cord Numbering
44
Figure 29: PSU Locations
45
Figure 30: Power Supply
45
2.10.2 Leaf Boards
46
Figure 31: Leaf Board Numbering
46
Figure 32: Ejector Handle
47
Figure 33: Leaf Release
47
Figure 34: Intact Vs Defected Signal Connectors
48
Figure 35: Intact Vs Defected Power Pin Holders
48
2.10.3 Spine Boards
49
Figure 36: Management Module Numbering
50
Figure 37: Spine Board Extraction
50
Figure 38: Intact Vs Defected Mechanics
52
Figure 39: Intact Vs Defected Side Signal Connectors
52
Figure 40: Intact Vs Defected Middle Signal Connectors
53
Figure 41: Intact Vs Defected Power Pin Holders
53
Figure 42: Spine Board Insertion Caution
53
2.10.4 Fan Modules
54
Figure 43: Leaf Fan Locations on the Chassis
54
Figure 44: Leaf Fan Module Extraction
55
Figure 45: Spine Fan Module
55
2.10.5 Management Module
56
Figure 46: Fan Status LED on the Spine Module
56
Figure 48: Intact Vs Defected Signal Connectors
57
Figure 49: Intact Vs Defected Power Pin Holders
58
2.10.6 Switch Shut-Down Procedures
59
Chapter 3 Interfaces
60
LED Status Indicators
60
Power Supply Unit Leds
60
Figure 50: Power Supply Unit Status Indications
60
Figure 51: PSU Cover on and off
61
Leaf Board LED Indicators
62
Table 4: Leaf Status LED
62
Table 5: Bad Port LED Configurations
62
Figure 52: Leaf Board Led Indicators
62
Spine Board LED Indicators
63
Table 6: Connector Physical and Logical Link Indications
63
Table 7: Spine Status LED
64
Table 8: Spine Fan Status LED
64
Figure 53: Spine Status Leds
64
Spine Side Panel Display LED Indicators
65
Table 9: Spine to Leaf IB Link Status
65
Table 10: Bad Port LED Configurations
65
Table 11: Leds Display for Normal Operation
66
Figure 54: Spine Side Panel Display Status Indications
66
Management Module LED Indicators
67
Figure 55: Management Module Status Indications
67
Figure 56: Management Module Leds
67
Table 12: Leds Display for Normal Operation
67
Port Connector Interfaces
68
Table 13: Management Module PSU LED Configurations
68
Table 14: Management Module S.fan LED Configurations
68
Table 15: Management Module L.fan LED Configurations
68
Table 16: Management Module MASTER LED Configurations
68
Air Flow
69
QSFP Cable Power Budget Classification
69
Management Module Interfaces
69
Figure 57: Port Numbering
69
Figure 58: Top and Bottom Ports
69
Figure 59: Management Module Interfaces
69
Console
70
I2C
70
MGT- Management
70
Reset - RST
70
Usb
70
Figure 60: Reset Button
71
Chapter 4 Chassis Power up
72
Power Supply and Spine Board Indicator Status at Power on
73
Figure 61: Spine Side Panel Display Status Indications
73
Figure 62: Management Module Status Indications for Normal Operation
73
Chapter 5 Switch Management Tools
74
Infiniband Subnet Manager
75
Fabric Inspector (Diagnostics)
75
Accessing the CPU Via the Ethernet Connector
75
Upgrading Software
75
Chapter 6 Troubleshooting
76
Power Supply Unit
76
Leaf Board
76
Management Module
77
Spine Board
78
MLNX-OS® Software
78
Chapter 7 Disassembly and Disposal
79
Disassembling the Chassis
79
Removing the Chassis
79
Removing the Bottom Shelf
79
Disposal
80
Appendix A Specification Data
81
Table 17: Switch Specification SX6512-[4N]R
81
A.1 EMI Certification
83
Approved Cables
83
EMI Certification
83
Appendix B Thermal Threshold Definitions
84
Appendix C Calculating the Weight of a Customized Chassis
85
Table 18: Switch System Weight Calculation
85
Appendix D Calculating the Power of a Chassis
86
Table 19: Power Consumption of Chassis Parts
86
Table 20: QSFP Cable Power Consumption
86
Table 21: Calculating Total Switch System Power Consumption
86
Figure 47: Management Module
86
Appendix E QSFP Interface
88
Table 22: Infiniband QSFP Connector Pinout
88
Figure 63: Infiniband QSFP Connector Symbol
89
Figure 64: QSFP Connector Male and Female Views
90
Appendix F Replacement Parts Ordering Numbers
91
Table 23: Replacement Parts Ordering Numbers
91
Appendix G Safety Warnings (Multiple Languages)
92
Nordic Countries Notices
92
Installation Safety Warnings (English)
92
安裝安全性警告 (Chinese)
99
Avertissements de Sécurité Pour L'installation (French)
102
Installation Sicherheitshinweise(German)
105
Advertencias de Seguridad de Instalación (Spanish)
109
Предупреждения По Технике Безопасности При Установке (Russian)
112
Avertismente Privind Siguranţa la Instalare (Romanian)
115
Sigurnosna Upozorenja Za Instaliranje (Croatian)
119
Avvertenze DI Sicurezza Per L'installazione (Italiano)
122
Advertisement
Mellanox Technologies MSX6512-4R Hardware Installation Manual (118 pages)
216-Port InfiniBand FDR SwitchX Switch Platform
Brand:
Mellanox Technologies
| Category:
Switch
| Size: 3 MB
Table of Contents
Table of Contents
3
List of Tables
5
List of Figures
6
Revision History
8
Table 1: Revision History of this User's Manual
8
Table 2: Reference Documents and Websites
9
Mellanox Part Numbering Legend
10
About this Manual
8
Chapter 1 Installation
11
Installation Safety Warnings
11
Environmental and Safety Recommendations
15
Chassis Package Contents
16
Leaf Package Contents
17
Spine Package Contents
17
Management Package Contents
17
Physical Installation
17
ESD Connection
18
Figure 1: Shelf Installation Kit Parts
19
Figure 2: Chassis Installation Parts
20
Figure 3: Shock and Tilt Stickers
21
Figure 4: Opening the Container
22
Figure 5: Placement of Chassis in Rack
23
Figure 6: Inserting the Caged Nuts for the Shelf
23
Figure 7: Connect Rail Slide to Rack Vertical Support
24
Figure 8: Inserting the Caged Nuts for the Faceplate
24
Figure 9: Chassis on Shelf with Filler Panel
25
Installing the Cable Holder
26
Figure 10: Cable Holders
26
Figure 11: Cable Holder Placement
27
Installing the Chassis
28
Figure 12: Chassis Rails and Rail Slides
28
Figure 13: Installing the Handles
29
Figure 14: Screw the Handles Onto the Chassis
29
Figure 15: the Rails Are Already Connected Onto the Chassis
30
Figure 16: Raising the Chassis Using a Mechanical Lift
31
Figure 17: Put on the Rail Slide
31
Figure 18: SX6512 Chassis on the Shelf
32
Figure 19: Face Plate Mounting Bolt Locations
32
Ground Connections
33
Power Connections
33
Figure 20: Ground Connection
33
Figure 21: Multiple Power Inlets - Electric Caution Notification
34
Powering up the Switch Platform
34
Infiniband QSFP Cable Installation
35
Figure 22: Spine Module
35
Cable Power Classes
36
Supported Approved Cables
36
Hot Swap Insertion and Extraction
36
1.10.1 Power Supply Units
37
Figure 23: Power Cord Numbering
37
Figure 24: PSU Locations
38
Figure 25: Power Supply
38
1.10.2 Leaf Boards
39
Figure 26: Leaf Board Numbering
39
Figure 27: Ejector Handle
40
Figure 28: Leaf Release
40
Figure 29: Intact Vs Defected Signal Connectors
41
Figure 30: Intact Vs Defected Power Pin Holders
41
1.10.3 Spine Boards
42
Figure 31: Management Module Numbering
43
Figure 32: Spine Board Extraction
43
Figure 33: Intact Vs Defected Mechanics
45
Figure 34: Intact Vs Defected Side Signal Connectors
45
Figure 35: Intact Vs Defected Middle Signal Connectors
46
Figure 36: Intact Vs Defected Power Pin Holders
46
Figure 37: Spine Board Insertion Caution
46
1.10.4 Fan Modules
47
Figure 38: Leaf Fan Locations on the Chassis
47
Figure 39: Leaf Fan Module Extraction
48
Figure 40: Spine Fan Module
48
1.10.5 Management Module
49
Figure 41: Fan Status LED on the Spine Module
49
Figure 42: Management Module
50
Figure 43: Intact Vs Defected Signal Connectors
50
Figure 44: Intact Vs Defected Power Pin Holders
51
1.10.6 Switch Shut-Down Procedures
52
Chapter 2 Interfaces
53
LED Status Indicators
53
Power Supply Unit Leds
53
Figure 45: Power Supply Unit Status Indications
53
Figure 46: PSU Cover on and off
54
Leaf Board LED Indicators
55
Table 3: Leaf Status LED
55
Table 4: Bad Port LED Configurations
55
Figure 47: Leaf Board Led Indicators
55
Spine Board LED Indicators
56
Table 5: Connector Physical and Logical Link Indications
56
Table 6: Spine Status LED
57
Table 7: Spine Fan Status LED
57
Figure 48: Spine Status Leds
57
Spine Side Panel Display LED Indicators
58
Table 8: Spine to Leaf IB Link Status
58
Table 9: Bad Port LED Configurations
58
Table 10: Leds Display for Normal Operation
59
Figure 49: Spine Side Panel Display Status Indications
59
Management Module LED Indicators
60
Table 11: Leds Display for Normal Operation
60
Figure 50: Management Module Status Indications
60
Figure 51: Management Module Leds
60
Port Connector Interfaces
61
Table 12: Management Module PSU LED Configurations
61
Table 13: Management Module S.fan LED Configurations
61
Table 14: Management Module L.fan LED Configurations
61
Table 15: Management Module MASTER LED Configurations
61
Air Flow
62
QSFP Cable Power Budget Classification
62
Management Module Interfaces
62
Figure 52: Port Numbering
62
Figure 53: Top and Bottom Ports
62
Figure 54: Management Module Interfaces
62
Console
63
I2C
63
MGT- Management
63
Usb
63
Reset - RST
63
Figure 55: Reset Button
64
Chapter 3 Chassis Power up
65
Power Supply and Spine Board Indicator Status at Power on
66
Figure 56: Spine Side Panel Display Status Indications
66
Figure 57: Management Module Status Indications for Normal Operation
66
Chapter 4 First-Time Configuration
67
Running the Wizard
67
Figure 58: Console Ports for Sx60Xx/Sx65Xx Managed Systems
67
Table 16: Serial Terminal Program Configuration
68
Table 17: Configuration Wizard Session - IP Configuration by DHCP
68
Table 18: Configuration Wizard Session - IP Zeroconf Configuration
70
Table 19: Configuration Wizard Session - Static IP Configuration
71
Re-Running the Wizard
72
Starting the Command Line (CLI)
72
Starting the Web User Interface
73
Figure 59: MLNX-OS Login Window
73
Figure 60: EULA Prompt
74
Figure 61: Display after Login
74
Chapter 5 Resetting the Switch - RST
75
Figure 62: Reset Button
75
Chapter 6 Troubleshooting
76
Power Supply Unit
76
Leaf Board
76
Management Module
77
Spine Board
78
MLNX-OS® Software
78
Chapter 7 Disassembly and Disposal
79
Disassembling the Chassis
79
Removing the Chassis
79
Removing the Bottom Shelf
79
Disposal
80
Appendix A Installation Safety Warnings
81
Installation Safety Warnings (English)
81
安裝安全性警告 (Chinese)
85
Avertissements de Sécurité Pour L'installation (French)
90
Installation Sicherheitshinweise(German)
95
A.4 Installation Sicherheitshinweise(German)
95
Advertencias de Seguridad de Instalación (Spanish)
99
Предупреждения По Технике Безопасности При Установке (Russian)
103
Avertismente Privind Siguranţa la Instalare (Romanian)
107
Sigurnosna Upozorenja Za Instaliranje (Croatian)
112
Mellanox Technologies MSX6512-4R Hardware Installation Manual (48 pages)
216 Port InfiniBand FDR Switch Platform
Brand:
Mellanox Technologies
| Category:
Switch
| Size: 0 MB
Table of Contents
Table of Contents
3
Table 1: Revision History of this User's Manual
6
Table 2: Reference Documents and Web Sites
7
Chapter 1 Chassis Installation
9
Environmental and Safety Recommendations
9
Chassis Package Contents
10
Leaf Package Contents
10
Spine Package Contents
11
Management Package Contents
11
Physical Installation
11
ESD (Electrostatic Discharge) Connection
11
Installation Procedure
12
Figure 1: Shock and Tilt Stickers
13
Figure 2: Shelf Installation Kit Parts
14
Figure 3: Inserting the Caged Nuts for the Shelf
16
Figure 4: Use These Holes for the Rail Slides
16
Figure 5: Connect Rail Slide to Rack Vertical Support
17
Figure 6: Inserting the Caged Nuts for the Faceplate
17
Installing the Chassis
18
Figure 7: Chassis Rails and Rail Slides
18
Figure 8: Screw the Handles Onto the Chassis
19
Figure 9: the Rails Are Already Connected Onto the Chassis
19
Figure 10: Chassis on the Shelf
20
Figure 11: Put on the Rail Slide
21
Figure 12: Face Plate Mounting Bolt Locations
21
Inserting the Leafs
22
Figure 13: Move the Rail Slide to the Vertical Support
22
Inserting a Management Module
23
Figure 14: Ejector Latch
23
Figure 15: Ejector Latch
23
Inserting a Spine Board
24
Figure 16: Spine Board Insertion
24
Figure 17: Ejector Latch
24
Chapter 2 Installing the Cable Holder
25
Figure 18: Cable Holders
25
Figure 19: Inserting the Caged Nuts for the Cable Holder
26
Figure 20: Cable Holder Placement
27
Chapter 3 Ground Connections
28
Figure 21: Ground Connection
28
Chapter 4 Power Connections
29
Powering up the Switch Platform
29
Figure 22: Multiple Power Inlets - Electric Caution Notification
30
Figure 23: Spine Module
30
Chapter 5 Infiniband QSFP Cable Installation
31
Port Connector Interfaces
31
Supported Approved Cables
32
Cable Power Classes
32
Figure 24: Port Numbering
32
Figure 25: Top and Bottom Ports
32
Chapter 6 Chassis Power up
33
Power Supply, Management Board, and Spine Board Indicator Status at Power on
34
Figure 26: Spine Side Panel Display Status Indications
34
Figure 27: Management Module Status Indications for Normal Operation
34
Chapter 7 Infiniband Fabric Initialization and Management
35
Configuring the Switch Management Modules for the First Time
35
Figure 28: Connecting the Harness to the Console
35
Table 3: Serial Terminal Program Configuration
36
Table 4: Configuration Wizard Session - IP Configuration by DHCP
36
Table 5: Configuration Wizard Session - IP Zeroconf Configuration
38
Table 6: Configuration Wizard Session - Static IP Configuration
39
Rerunning the Wizard
40
Chapter 8 MLNX-OS Management Software
41
Starting an SSH Connection to the Switch
41
Starting a Webui Connection to the Switch
41
Figure 29: Web UI Login Page
42
Chapter 9 Resetting the Switch - RST
43
Figure 30: Reset Button
43
Chapter 10 Troubleshooting
44
Power Supply Unit
44
Leaf Board
44
Management Module
45
Yellow Status LED (for the Chassis) on the Management Module Is Lit
45
Yellow LED for the Leaf Fan on the Management Module Is Lit
45
Yellow LED for the Spine Fan on the Management Module Is Lit
46
Spine Board
46
MLNX-OS Software
46
Advertisement
Advertisement
Related Products
Mellanox Technologies MSX6512-NR
Mellanox Technologies MSX6536-NR
Mellanox Technologies MSX6536-10R
Mellanox Technologies MSX 6518-NR
Mellanox Technologies MSX6506-3R
Mellanox Technologies MSX6506-NR
Mellanox Technologies MSX6518-6R
Mellanox Technologies SwitchX MSX6018F-1BRS
Mellanox Technologies SwitchX-2 MSX6012F-1BRS
Mellanox Technologies SwitchX-2 MSX6005F-1BFS
Mellanox Technologies Categories
Switch
Computer Hardware
Adapter
Network Card
Network Router
More Mellanox Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL