1.10.2 Leaf Boards - Mellanox Technologies MSX6536-10R Hardware Installation Manual

648-port infiniband fdr switchx switch platform
Hide thumbs Also See for MSX6536-10R:
Table of Contents

Advertisement

InfiniBand FDR Switch Platform Hardware User Manual
4. Insert the power cord into the supply connector on the other side of the chassis.
5. Replace the cover over the PSUs.

1.10.2 Leaf Boards

The leaf boards are numbered from top to bottom, with corresponding numbers dis-
played to the outside of the leafs vertically along the side panel.
Mellanox Technologies
The green indicators should light. If not, extract the PSU and re-insert it again.
Do NOT mix replacement parts based on different generations of chip.
Do not install InfiniScale IV based replacement parts within a SwitchX® based chas-
sis and vice versa. All Replacement modules must be consistent with the Chassis fam-
ily and switch chip generation.
When hot-swapping any of the units, it is necessary to wait 1 minute after removing
the defective part before inserting the new part. This is necessary so that the manage-
ment module will start a new cycle checking through the leafs and spines for the FW
versions.
Rev 1.7