1.9.2.1 Extracting a Leaf Board
Each leaf board has a ejector handle that locks the board in place and serves as a lever for
seating or extracting (see Figure 26).
1. Run the shut down command
down leaf 16 run the command below.
switch [master] (config) # no power enable L16
2. Disconnect all cables connected to the leaf.
3. Push the ejector handle to unlock the ejector from the chassis.
4. Open the ejector until it is 45 degrees from the leaf.
Push the ejector handle
5. Pull out the module half-way through the guiding rails using the ejector handle.
6. Lock the ejector handle.
7. Hold the body of the leaf on both sides and remove it from the chassis.
Mellanox Technologies

Figure 25: Leaf Board Numbering

3
5
7
9
10 11
13
14 15
2
4
6
8
12
3
5
7
9
10 11
13
14 15
2
4
6
8
12
3
5
7
9
10 11
13
14 15
2
4
6
8
12
"no power enable <module>".

Figure 26: Ejector Handle

Ejector handle
The board is short, therefore do not let go of it while sliding it out.
F
D
R
16 17
1
3
5
7
18
2
4
6
UID
F
D
R
16 17
1
3
5
7
18
2
4
6
UID
F
D
R
16 17
1
3
5
7
18
2
4
6
UID
Pull the leaf out of the chassis
9
10 11
13
14 15
16 17
8
12
18
L2
9
10 11
13
14 15
16 17
8
12
18
L4
9
10 11
13
14 15
16 17
8
12
18
L12
For example to shut