1.10.4 Fan Modules; Figure 46: Spine Board Insertion Caution - Mellanox Technologies MSX6536-10R Hardware Installation Manual

648-port infiniband fdr switchx switch platform
Hide thumbs Also See for MSX6536-10R:
Table of Contents

Advertisement

InfiniBand FDR Switch Platform Hardware User Manual
5. Note the following sticker placed on the top of the spine board.
6. Start with the ejector handles fully open; that is, at 45 degrees to the front panel of the
spine.
7. Holding the spine by its sides, carefully set the spine board into the chassis.
8. Using only the ejector handles, slowly slide the board into the chassis until the hooks
reach the vertical bar.
9. Catch the hooks onto the vertical bar of the chassis and push the ejector handle shut.
10. Lock the ejector handles onto the board.

1.10.4 Fan Modules

There are eight fan modules on the chassis for the leafs. They are located on both sides of
the chassis; four on the leaf side corners and four on the spine side corners. When a fan
module is not functioning the status LED on the fan will light up.
Each spine has an individual fan module that contains two individual fans. Should a sin-
gle fan fail the Fan Status LED on the spine and the S. Fan LED on the management
module will light, indicating the necessity to replace the fan module. Air flow through
the spines is independent of the air flow through the leafs.
Mellanox Technologies

Figure 46: Spine Board Insertion Caution

Do not use the fan FRU handle to insert the spine board.
Do not apply excessive force to slide in the spine board. If you feel resistance, remove
the spine and double check both the chassis and spine for any damage.
There are two different fan modules for the chassis. These fans have different model
numbers and are not interchangeable. The fans on the leaf side of the chassis are
MTF005001, whereas the fans on the spine side of the chassis are MTF005002.
Rev 1.7
51