Item
Number of measurement
programs
Window shape
Distance and angle
measurement
Arithmetic operation
Other functions
Input relays
Output relays
Auxiliary relays
Timers
Counters
Parallel interface
General-purpose
serial interface
Computer link
Image output
Number of cameras
Make settings
Measu-
Internal trigger
rement
start
External trigger
input
Interrupt processing
input
Inputs
Common for input
Output
Common for output
Power supply
Power voltage/consumption
Maximum 6 per object type (measurement 0 - camera 1, measurement 0 -
camera 2, measurements 1 to 4)
Note: Measurement 0 is only used for positional deviation measurement.
Rectangle, circle, oval (when using area measurement by binary
conversion, object counting by binary conversion, object identification by
binary measurement), polygon window (maximum 32 sided polygons: When
binary area measurement, counting after binary conversion, or object
identification (labeling) after binary conversion is selected.)
Measure distance (between two points, X coordinate, Y coordinate),
measure angle (3 points, 2 points against horizontal line, 2 points against
vertical line), auxiliary point (center, circle center, gravity center, line over 2
points, crossing point of two straight lines)
Four basic operations (+, -, X, /), root, absolute value, TAN, ATAN,
maximum, minimum, average , total.
Display measuring time, light level monitor function, crosshair cursor
display, change display language between Japanese and English, Run
screen lock function, setting menu display "yes/no", change image display
(through/freeze), change image brightness (bright/dark)
Parallel input: 7 points (X0 to X6)
Parallel output: 8 points (Y0 to Y7)
General-purpose serial interface, computer link: 16 points (Y0 to Y15)
128 points (C0 to C127), special area 18 points (C110 to C127)
8 points (TM0 to TM7), timer setting range: 0.01 to 9.99 seconds
(countdown timer)
8 points (CN0 to CN7), counter setting range: 001 to 999 (counts down)
Input: 7 points, 12/24 VDC
Output: 9 points, 12/24 VDC
RS232C/RS422 (2.4 to 115.2 kbps)
Built-in compatibility with certain SHARP, OMRON, and Mitsubishi models
1 channel, EIA 525 lines, 2:1 interlace
Maximum of 2
Using the IV-S30RK1 remote keypad and/or the IV-S30SP parameter
setting support software
CCD trigger (using the CCD camera)
Trigger input (parallel I/F), general-purpose serial I/F, keypad trigger (for
manual measuring)
1 point: External trigger (X0)
4 points: Object type change (X1 to X4)
2 points: External input (X5, X6)
1 point: + common
9 points: 1 READY , 8 user settable logical outputs (Y0 to Y7)
1 point: + common
2 points: +24 VDC, 0 V
24 VDC (±10 %) 7 W