15-4 Program examples (shape and positional deviation inspection)

(1) Outline
The positional deviation measurement (one point search) in measurement 0 allows the degree of
match and coordinates to be measured, and the result, OK or NG, is output.
Shape NG
(degree of match NG)
Evaluation
condition
(acceptable
range)
(2) Output conditions and ladder circuit for measurement 0 using camera 1
When the X coordinate, Y coordinate and degree of match are within acceptable ranges, the
auxiliary relay C000 is turned ON.
00X0
Coordi-
nate X
(3) Final output conditions and ladder circuit
C119
15
Measurement
termination
C118
Measurement operation error
C117
Illuminance monitor error
Reference image (registration No.0)
Positional deviation NG
(X coordinate, Y coordinate NG)
Coordinate (model 0-X): 200.0 to 250.0
Coordinate (model 0-Y): 150.0 to 200.0
Degree of match (model 0): +09500 to +10000
00Y0
00M0
Coordi-
Degree
nate Y
of match
C000
OK
Object to be measured
Reference image
registration window
Search area
C000
OK
Y00
NG output
Y01
Measurement operation
error output
Y02
Illuminance monitor
error output