Setting Numerical Data Of The Any Output Measuring - Sharp IV-S30J User Manual

Compact image sensor camera
Table of Contents

Advertisement

Communication (General Purpose Serial Interface)

[4] Setting numerical data of the any output measuring

Numerical data of the any setting of the response at measuring (code 14
measurement data 4 (code 24
Station
No.
:
[Any type of numerical data]
Output
code
1
2
Note: A maximum of 1 K bytes data is allowed.
[Ex.] A numerical data of the any setting when outputting coordinate X and coordinate Y with the
positional deviation measurements.
,
0 2
Codes and number of bytes of output data
1. Result of each measurement program
Kind of output
Degree of match
Coordinate X
Coordinate Y
Coordinate deviation X
Coordinate deviation Y
Angle
Average light level 1
Number of objects
Distance
Lead width
Lead length/
lead width 2
Total area
Area of each
label
17
X coordinate
of gravity
center/Distan-
ce between
gravity
centers X
Y coordinate
of gravity
center/Distan-
ce between
gravity
centers Y
: page 17-10) is as follows.
(H)
[Ex.] Response to code 24
Object
type
2 4
RC
RC
Any numerical data
(H)
(L)
1
2
Numeric result data3
3
Registration 0
Registration 0
(Model 0)
(Model 1)
Output data
01
02
03
04
05
06
07
08
MAX.
09
MIN.
0A
MAX.
0B
MIN.
0C
MAX.
0D
MIN.
0E
10
CUR.
11
MAX.
12
MIN.
13
CTR. OF
14
GRAVITY
MAX.
15
DIST.
MIN.
16
DIST.
CTR. OF
17
GRAVITY
MAX.
18
DIST.
MIN.
19
DIST.
SC
SC
CR
(H)
(L)
Delimiter between output data:","(Space 20
Output code list
Numeric result data
Output only the registered data in each specified
measurement, in register order.
Registration N
(Model 1)
,
0 3
:
Measurement program
2
O
O
2
O
O
2
O
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
4
4
2
2
17-16
: page 17-8) and reading
(H)
+ comma 2C
)
(H)
(H)
Registration 0
Registration N
(Model 0)
(Model 1)
:
O
O
O
O
O
O
O
O
O
O

Hide quick links: