Numerical Calculations
(5) Operations on the "FINAL OUTPUT COND" screen
1. Select "FINAL OUTPUT COND" on the "SELECT OBJECT TYPE
COND" screen, to display the final output conditions screen.
2. Move the cursor to "INPUT00" and row 0, and
press the SET key. Select "AUX. RLY-C."
from the popup menu and press the SET key.
The following logical symbol will be displayed in the left most column of INPUT 0.
[PAGE0]
INPUT0
LOGIC
3. Move the cursor to the "OUT" row using the left and right arrow keys, and press the SET key.
14
Select "OUTPUT Y" from the popup menu and press the SET key.
4. Now, a list of the Y outputs will be displayed. Select "Y0" using the up and down arrow keys, and
press the SET key.
The output coil for INPUT 0 will be displayed.
[PAGE0]
INPUT0
LOGIC
5. Press the TRG/BRT key to move the cursor to the upper function
menu. Then select "SCREEN" and press the SET key. Select "OPS-
MENU" from the popup menu and press the SET key.
Select the operation screen.
OUTPUT COND SCREEN SAVE
0
1
INPUT00
LOGIC
INPUT01
AUX.RLY-C
LOGIC
EXT-INP X
INPUT02
TMR TM
LOGIC
CNTR CN
INPUT03
AN
LOGIC
OUTPUT Y
INPUT04
LOGIC
INPUT05
LOGIC
INPUT06
LOGIC
INPUT07
LOGIC
SET=SELECT TYPE SEC=BACK SEL=CHNG IMG TRG=FUNC
OUTPUT
OUTPUT
14-14
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS (NEW)
MEA-CND(CAMERA2)
FINAL NUM.CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
TYPE(NEW)
F C1 BRT
OUT
2
3
4
5
6
7
OUTPUT Y
AUX.RLY-C
TMR TM
CNTR CN
DEL
Y OUTPUT Use place
Y0
FINAL OUTPUT COND
Y1
NO
Y2
NO
Y3
NO
Y4
NO
Y5
NO
Y6
NO
Y7
NO