Setting the Input/Output Conditions
(10) Measurement start input = CCD trigger, start sampling = auto, object type change = general
purpose serial, result output = general purpose serial/parallel
The general purpose serial command (code 55
Setting order 1
1MEAS INP I/F
2 START CCD SAMPL
3 OUTPUT OBJ TYPE
16
2 (
3)
PARALLEL+SERIAL
TRIG CCD START
AUTO(EDGE)
AUTO(LEVEL)
Select one of
PARALLEL
these.
SERIAL
PARALLEL
SERIAL
) is used to change the object type.
(H)
Configuration example
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Personal computer
Remote key pad
Power supply (24 VDC)
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
Black White
Work
CCD trigger
Edge
Measurement
Level
16-16
Data
Monitor
Controller