Setting the Input/Output Conditions
(9) Measurement start input = CCD trigger, start sampling = auto, object type change, result
output = parallel
Setting order 1
1MEAS INP I/F
2 START CCD SAMPL
Select one of
these.
3 OUTPUT OBJ TYPE
Time chart (when auto mode (edge) is selected for as the CCD sampling start)
CCD trigger
cycle
Type selection
input
See page
16-5.
CCD trigger
window
16
(not highlighted)
READY output
(While measuring
or setting = L)
PC calculation
condition
Parallel output
(Y0 to Y7)
2 (
3)
PARALLEL+SERIAL
TRIG CCD START
AUTO(EDGE)
AUTO(LEVEL)
PARALLEL
SERIAL
PARALLEL
SERIAL
Specified object type number
Black
White
Trigger
Measurement result is valid
at the end of a measurement
P
P
P
P
Halt PC operation
C
C
C
C
during measurement
When the object type is changed, all Y
output and auxiliary relays turn OFF.
Configuration example
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Remote key pad
Controller
Power supply
(24 VDC)
Warning lamp
External output
(Y0 to Y7)
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
Black White
Work
CCD trigger
Edge
Measurement
Level
Restarts CCD sampling automatically after
measurement is completed.
Black
White
Trigger
P
P
P
P
P
P
P
P
P
Halt PC operation
C
C
C
C
C
C
C
C
C
during measurement
Parallel output is valid for PC control after
the measurement result is determined.
Result output
16-14
Monitor
Start sampling input
X0
(photo sensor or
proximity sensor)
Type selection switch
Black
P
P
P
P
P
C
C
C
C
C
Result output