18-5 Specifications for any output data

When the serial output is set to "ANY" (page 16-26), the measurement results for the output data that
is set to "YES" will be written into the write register map "output data from measurements 0 to 4 (block
0): *6 on page 18-3," in output-code order.
Measurement
Measurement 0
Camera1
Measurement 0
Camera2
Measurement 1
Measurement 2
Measurement 3
Measurement 4
- Data that are set to "NO" output do not output any signal (scrolled up).
- Set the next page for details about the output codes (type, number of bytes, related measurement
programs)
Ex.: Output data examples when the "SERIAL OUTPUT" column is set to "YES."
SHARP Mitsubishi
09014
D0006
09015
09016
D0007
09017
09020
D0008
09021
09022
D0009
09023
09024
D0010
09025
09026
D00011
09027
09030
18
D00012
09031
09032
D00013
09033
Output
Output code 01
(degree of match)
Output code 02
(coordinate X)
to
Output code 40
(numeric
calculation)
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
Output
OMRON
data
L
L
00
0100
DM0006
H
H
01
L
L
78
DM0007
2678
H
H
26
L
L
00
0200
DM0008
H
H
02
L
L
92
DM0009
0992
H
H
09
L
L
00
0005
DM0010
H
H
05
(coordinate Y deviation)
L
L
FA
DM00011
00FA
H
H
00
L
L
01
0001
DM00012
H
H
00
L
L
28
DM00013
2628
H
H
26
Registration
Degree of match for register number 0
Degree of match for register number 1
to
Degree of match for register number 7
Coordinate X for register number 0
Coordinate X for register number 1
to
Coordinate X for register number 7
to
Numeric calculation result for register number 0
Numeric calculation result for register number 1
to
Numeric calculation result for register number 15
Details
: 00 = fixed value
(H)
01 = output code (degree of match)
: 9848
= 98.48%
(H)
(D)
: 00 = fixed value
(H)
02 = output code (X coordinate)
: 2450
= 245.0 (coordinate value)
(H)
(D)
: 00 = fixed value,05 = output code
(H)
: 250
= 25.0 (deviation value)
(H)
(D)
: 00 = fixed value
(H)
01 = output code (degree of match)
: 9752
= 97.52%
(H)
(D)
18-16
Measurement item
when SERIAL
OUTPUT is set to
"YES"
Register 0 (degree of
match, coordinate X,
coordinate Y
deviation) for
measurement 1
(position deviation
measurement)
Register 0 (degree of
match) for
measurement 3
(degree of match
inspection)