Chapter 17: Communication (General Purpose Serial Interface); List Of Processing Functions - Sharp IV-S30J User Manual

Compact image sensor camera
Table of Contents

Advertisement

Chapter 17: Communication (General Purpose Serial Interface)

The IV-S30J can communicate with a personal computer that transmits commands and receives responses to
measurement execution commands.

17-1 List of processing functions

The following functions can be used for communication between the IV-S30J and a personal
computer (using the general-purpose serial interface).
Cate-
Processing
gory
description
Measurement
execution
function 1
Measurement
execution
function 2
Measurement
execution
function 3
Measurement
execution
function 4
Measurement
data reading 1
Measurement
data reading 2
Measurement
data reading 3
Measurement
data reading 4
Illumination
reading
Corrected light
level reading
Shown below is the relationship of each selection when code 10 to 14 are specified is shown below.
The conditions below are what is shown when the "PARALLEL+SERIAL" is selected on the "
INP I/F" on the "I/O CONDITIONS" selection screen.
Measurement
start
General purpose
---
serial port
None
Computer link
Parallel port
General-purpose
serial
Communication (General Purpose Serial Interface)
Code
- Executes all measurement programs for a specified object type.
10
(You can make measurements by specifying a camera.)
- Outputs the ladder results (Y0 to 15).
- Executes all measurement programs for a specified object type.
(You can make measurements by specifying a camera.)
11
- Outputs the ladder results (Y0 to 15) and the measurement
data in block 0 for each measurement program.
- Executes all measurement programs for a specified object type.
(You can make measurements by specifying a camera.)
12
- Outputs the ladder results (Y0 to 15) and the measurement
result from a specified block for a specified measurement
number.
- Executes all measurement programs for a specified object type.
14
(You can make measurements by specifying a camera.)
- Outputs any numerical data selected by the IV-S30J.
Reads the result of the last measurement
20
- Outputs the ladder results (Y0 to 15).
Reads the result of the last measurement
21
- Outputs the ladder results (Y0 to 15) and the measurement
data in block 0 for each measurement program.
Reads the result of the last measurement
22
- Outputs the ladder results (Y0 to 15) and the measurement
result from a specified block for a specified measurement number.
- Reads the results of the last measurement from a specified
24
measurement code.
- Outputs any numerical data selected by the IV-S30J.
- Reads the amount of illumination measured by the lighting
28
monitor function, and the evaluation result.
- Reads the corrected light level measured by the lighting monitor
29
function, evaluation result and preset reference density.
Output
Serial output
selection
Command codes 10 to 12
---
SHARP/MITSUBISHI/
OMRON/YOKOGAWA
Response output from
command codes 11
17-1
Functions
Object type change
Command codes 10 to 12
Parallel
Parallel
Parallel
MEAS
17