How to display the distance and angle conditions setting screen
There are two methods for displaying the distance and angle conditions setting screen.
1) On the "MEASUREMENT 1", "MEAS CND", or
"REG COND" screen, press the TRG/BRG
key to move the cursor to the upper function
menu. Select "COND' using the left and right
keys and press the SET key. Select
"DST&ANGL" from the popup menu.
2) On the SELECT OBJECT TYPE COND
screen, select "TYPE00" -> "MEA-
CND(CAMERA1)" -> "MEAS01(POSI-
DEVIATION)" -> "DISTANCE&ANGLE
COND," in that order.
Setting the distance and angle conditions
OBJ
Select object type you want to measure. The
object types available are: "AUX" (auxiliary),
"DST" (distance), and "ANGL" (angle). The
setting details are different for each type.
"AUX": See page 13-4.
"DST": See page 13-6.
"ANGL": See page 13-7.
Distance and Angle Measurement
MEASUREMENT 1 SCREEN COND SAVE
1MEAS SELECTION POSI-DEVEATION
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS01(POSI-DEVIATION)
IMG PRE-PROC
MEAS CND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
DIST&AGL COND SCREEN COND SAVE
1OBJ
DST
2DISTANCE NO
00(0~15)
3DESTANCE
NO
REGISTER NO.
DISTANCE
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNK
13-3
F C1 BRT
IMG PRE-PROC
MEAS
EVALUATION
DST&ANGL
NUM-CALC
OUT
F C1 BRT
F C1 BRT
AUX
DST
ANGL
[TEST RESULT]