[3] Evaluation conditions

The setting details and procedures for setting the evaluation conditions are the same for all measurement
programs.
Evaluation conditions [EVALUATION COND] menu for measuring degree of match
EVALUAT COND SCREEN COND SAVE
1REGISTER
2CONDITION SET RESET AUTO( 10%)
3MATCH LVL (MDL0) -10000~+10000
4X COORD. (MDL0) 000.0~511.0
5 COORD. (MDL0)
6GLAY LVL (MDL0) 000.0~255.0
7MATCH LVL (MDL1) -10000~+10000
8X COORD. (MDL1) 000.0~511.0
9Y COORD. (MDL1) 000.0~479.0
0GLAY LVL (MDL1) 000.0~255.0
qTEST
EXEC(WITH-POSI. ADJ WITHOUT-POSI.ADJ)
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
If you select "WITH-POSI.ADJ," the system will conduct test
while adjusting for positional deviation. - pages 3-30 to 3-32.
Condition setting
Upper and lower limit values of the all evaluation condition items can be set automatically
with the following processes.
After testing more than one good workpieces, the IV-S30J automatically set the limits based
on the test results.
Condition
settings
AUTO
**%)
[TEST RESULT]
M0=+09000
X0= 000.0
~
G0= 116.0
M1=+09000
X1= 000.0
Y1= 000.0
G1= 116.0
- Multiple the specified rate ( %) on the newly tested good workpieces,
and compared this value with the range between the current upper and
lower limits. If it is outside the upper and lower limits, the IV-S30
renews the maximum or minimum value with this value.
At the first setting, the first test result will be the upper and lower limit
without any condition.
**%]
The value from
00% to
1%. (Default value =
10%)
To enter this position, move the cursor to the "AUTO" position and press
the up and down keys to change the value. After determining the value,
press the SET key, upper and lower limits of each item will be
automatically set with tis %.be the upper and lower limit without any
condition.
3-17
Setting the Conditions for Each Object Type
The "degree of match + 09000"
refers to a degree of match (match
[OUTPUT]
between individual pixels) between
the registered image and the
OK
NO
measured image that is equal to
90.00% or more of the total.
OK
NO
OK
NO
Using the up and down keys, you
OK
NO
can set the output to NO (no out-
put), Y0 to 7 (output on these re-
OK
NO
lays), or C000 to C127 (output on
OK
NO
these secondary relays), in the out-
OK
NO
put area of the menu.
OK
NO
(If the test result returns OK, then
the output is turned ON. If it is NG,
then it is turned OFF).
When carrying out a test using item
qTEST, on the menu, the result-
ing measurement values and the
evaluation (OK or NG) will be dis-
played.
Details
99% can be entered to the " **%" in units of