18-6 Interface

The interface between the IV-S30J and a programmable controller from each manufacturer is
described below.
IV-S30J
Settings for the IV-S30J
See item [1] below.

[1] Setting items for the IV-S30J

Item
Communication speed(k bit/sec)
Data length (bit)
Parity
Stop bit
Error check
Station No.
Write address
(up to 512 bytes)
Programmable
controller
Sharp
Mitsubishi
OMRON
Yokogawa
Setting details
115.2, 57.6, 38.4, 19.2, 9.6, 4.8, 2.4
7, 8
None, odd, even
1, 2
Checksum
Sharp:
00 to 37
(8)
Mitsubishi: 00 to 31
OMRON: 00 to 31
Yokogawa: 01 to 32
Sharp:
09000 to 99776
Mitsubishi: D0000 to D9999
OMRON: DM0000 to DM9999
Yokogawa: D00001 to D16384
18-19
[2]
[3]
[4]
Computer Link