Chapter 62 Network Management Commands - D-Link xStack DGS-3420 Series Reference Manual

Layer 2 managed stackable gigabit switch cli
Hide thumbs Also See for xStack DGS-3420 Series:
Table of Contents

Advertisement

xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
Chapter 62
enable snmp
disable snmp
show snmp
create trusted_host [<ipaddr> | <ipv6addr> | network <network_address> | ipv6_prefix
<ipv6networkaddr>] {snmp | telnet | ssh | http | https | ping}
config trusted_host [<ipaddr> | <ipv6addr> | network <network_address> | ipv6_prefix
<ipv6networkaddr>] [add | delete] {snmp | telnet | ssh | http | https | ping | all}
delete trusted_host [ipaddr <ipaddr> | ipv6address <ipv6addr> | network <network_address>|
ipv6_prefix <ipv6networkaddr> | all]
show trusted_host
config snmp system_name <sw_name>
config snmp system_location <sw_location>
config snmp system_contact <sw_contact>
enable snmp traps
disable snmp traps
enable snmp authenticate_traps
disable snmp authenticate_traps
enable snmp linkchange_traps
disable snmp linkchange_traps
show snmp traps {linkchange_traps {ports <portlist>}}
config snmp linkchange_traps ports [all | <portlist>] [enable | disable]
config snmp coldstart_traps [enable | disable]
config snmp warmstart_traps [enable | disable]
config trap source_ipif [<ipif_name 12> {<ipaddr> | <ipv6addr>} | none]
show trap source_ipif
config rmon trap {rising_alarm [enable | disable] | falling_alarm [enable | disable]}
show rmon
62-1
enable snmp
Description
This command is used to enable the SNMP function. When SNMP function is disabled, the network
manager will not be able to access SNMP MIB objects. The device will not send traps or notification to
network manager either.
Format
enable snmp
Parameters
None.
Network
Management Commands
690