AudioCodes Mediant 2000 User Manual page 536

Voip media gateway sip protocol
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

Parameter
[CASTablesNum]
CAS State Machines Parameters
Note: For configuring the CAS State Machine table using the Web interface, see ''Configuring CAS
State Machines'' on page 216.
Web: Generate Digit On Time
[CASStateMachineGenerateDi
gitOnTime]
Web: Generate Inter Digit Time
[CASStateMachineGenerateIn
terDigitTime]
Web: DTMF Max Detection
Time
[CASStateMachineDTMFMax
OnDetectionTime]
Web: DTMF Min Detection Time
[CASStateMachineDTMFMinO
nDetectionTime]
Web: MAX Incoming Address
Digits
[CASStateMachineMaxNumOf
IncomingAddressDigits]
Web: MAX Incoming ANI Digits
[CASStateMachineMaxNumOf
IncomingANIDigits]
Web: Collect ANI
[CASStateMachineCollectANI]
Web: Digit Signaling System
[CASStateMachineDigitSignal
ingSystem]
SIP User's Manual
the entire trunk is used, configured by the parameter
CASTableIndex.
Defines how many CAS protocol configurations files are loaded.
The valid range is 1 to 8.
Note: For this parameter to take effect, a device reset is required.
Generates digit on-time (in msec).
The value must be a positive value. The default value is -1.
Generates digit off-time (in msec).
The value must be a positive value. The default value is -1.
Detects digit maximum on time (according to DSP detection
information event) in msec units.
The value must be a positive value. The default value is -1.
Detects digit minimum on time (according to DSP detection
information event) in msec units. The digit time length must be
longer than this value to receive a detection. Any number may be
used, but the value must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default value is -1.
Defines the limitation for the maximum address digits that need to
be collected. After reaching this number of digits, the collection of
address digits is stopped.
The value must be an integer. The default value is -1.
Defines the limitation for the maximum ANI digits that need to be
collected. After reaching this number of digits, the collection of ANI
digits is stopped.
The value must be an integer. The default value is -1.
In some cases, when the state machine handles the ANI collection
(not related to MFCR2), you can enable the state machine to
collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value.
536
Description
Document #: LTRT-68814
Mediant 2000

Advertisement

Table of Contents
loading