AudioCodes Mediant 2000 User Manual page 217

Voip media gateway sip protocol
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

SIP User's Manual
Table 18-1: CAS State Machine Parameters Description
Parameter
Generate Digit On Time
[CasStateMachineGenerateDigitOnTim
e]
Generate Inter Digit Time
[CasStateMachineGenerateInterDigitTi
me]
DTMF Max Detection Time
[CasStateMachineDTMFMaxOnDetecti
onTime]
DTMF Min Detection Time
[CasStateMachineDTMFMinOnDetectio
nTime]
MAX Incoming Address Digits
[CasStateMachineMaxNumOfIncoming
AddressDigits]
MAX Incoming ANI Digits
[CasStateMachineMaxNumOfIncoming
ANIDigits]
Collet ANI
[CasStateMachineCollectANI]
Digit Signaling System
[CasStateMachineDigitSignalingSyste
m]
Version 6.4
Generates digit on-time (in msec).
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
Generates digit off-time (in msec).
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
Detects digit maximum on time (according to DSP
detection information event) in msec units.
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
Detects digit minimum on time (according to DSP
detection information event) in msec units. The digit time
length must be longer than this value to receive a
detection. Any number may be used, but the value must
be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
Defines the limitation for the maximum address digits that
need to be collected. After reaching this number of digits,
the collection of address digits is stopped.
The value must be an integer. The default value is -1 (use
value from CAS state machine).
Defines the limitation for the maximum ANI digits that
need to be collected. After reaching this number of digits,
the collection of ANI digits is stopped.
The value must be an integer. The default value is -1 (use
value from CAS state machine).
In some cases, when the state machine handles the ANI
collection (not related to MFCR2), you can control the
state machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value - use value from CAS
state machine.
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value - use value from CAS
state machine.
217
18. GW and IP to IP
Description
November 2011

Advertisement

Table of Contents
loading

Table of Contents