Kyocera Mita FS-8000CD Operation Manual page 75

Color printer
Hide thumbs Also See for FS-8000CD:
Table of Contents

Advertisement

3.5 Changing the Interface Parameters
6
Press the
key. One of the following serial parameters is indicated (Baud rate for
example).
Pressing the
or
the serial parameter, press the ENTER key. Use the
selection.
>Baud rate
9600
>Data bits
8
>Stop bits
1
>Parity
None
>Protocol
DTR(pos.)&XON
>Barcode Mode
Off
Barcode mode is used when the option barcode reader is connected to the printer to support
reading document IDs (barcodes). Note that Barcode Mode appears in the menu only when
a hard disk option is installed.
For example, to change baud rate from 9600 to 115200, display the baud rate menu following
the above procedure. When the display shows baud rate, 9600 (bps), press the ENTER key. A
blinking question mark (?) appears.
>Baud Rate
?
9600
key toggles through the serial parameters as follows. To change
Range
1200, 2400, 4800, 9600 (Default), 19200, 38400, 57600,
115200
7 or 8 (Default)
1 (Default) or 2
None (Default), Odd, Even, or Ignore
DTR (pos.) & Xon (Default), DTR (positive), DTR (neg-
ative), Xon/Xoff, ETX/ACK
Off (Default) or On
3-40
or
key to change the value or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-8000cFs-8000cn

Table of Contents