4-24 Configuring Your Server
Server
When the cursor is moved to the [Server] position, the Server menu is displayed. If an item with an
arrow displayed to its left (all menus in this section) is selected and then the Enter key is pressed, a
submenu is displayed in which settings are specified.
This section describes the options that can be specified on the Server menu and their functions. If
[System Management], [BMC LAN Configuration], or [Event Log Configuration] is selected and
then the Enter key is pressed, a submenu is displayed in which settings are specified.
For details about the options, see the following table.
Option
System
Management
BMC LAN
Configuration
Event Log
Configuration
Assert NMI on
PERR
Assert NMI on
SERR
FRB-2 Policy
Boot Monitoring
Parameters
–
–
–
Disabled
[Enabled]
Disabled
[Enabled]
[Retry 3 Times]
Disable FRB2 Timer
Always Reset
[Disabled]
5 to 60 minutes
Description
Specify whether to support PCI PERR.
Specify whether to support PCI SERR.
Specify the system operation when an FRB level 2
error occurs.
Specify whether to enable or disable the boot
monitoring function on booting, or select the
timeout time limit.
To use this function, install NEC ESMPRO Agent.
Set this item to [Disabled] if the system is booted
from an OS without NEC ESMPRO Agent
installed.
–
–
–