Check Consistency fails:
Is virtual disk "Degraded"?
Replace the failed hard disk drive with new one, then perform Rebuild.
Is RAID0 configured for virtual disk?
RAID0 has no data redundancy, therefore, Check Consistency is disabled in the
RAID0 configuration.
Cannot set Write-Back for cache mode:
The current cache mode of RAID controller is displayed on [Virtual Disks] -
[Properties] - [Policies] - "Write". If additional battery is faulty, is not connected,
or insufficiently charged, the cache mode is changed to "WThru (Write Through)"
even if you specify "WBack (Write Back)". See Chapter 4 for details.
Event ID129:
The following message appears on Windows Event Log.
Source:
Event ID:
Type:
Description:
Retry by OS has succeeded. It is not the problem in operating the system.
Event ID317:
The following message may be registered in RAID log in Universal RAID Utility and OS
log (Event Log or Windows, syslog of Linux).
Source:
Event ID:
Type:
Description:
Single-shot message indicates the successful retry even if the message above is
registered. If this message is repeatedly registered, physical device may be faulty.
Contact your service representative.
Access LED flashes:
Access LED flashes frequently even while the hard disk drive is not accessed.
The Access LED flashes if Patrol Read is running. With SATA hard disk drive, the
LED may stay on.
msas2k3
129
Warning
Information about Event ID (129) (Source: msas2k3) is not found.
-----
Raidsrv
317 (8000013D)
Warning
<RU0317>[CTRL: %1 PD:%2(%3) %4 %5] An error of warning level
occurred on physical device.
Error code: %6