On-screen message
BB Temp 2 Alm 00
BB Temp 2 Alm 02
BB Temp 2 Alm 07
BB Temp 2 Alm 09
Proc Temp Alm 00
Proc Temp Alm 02
Proc Temp Alm 07
Proc Temp Alm 09
Proc therm %07
Proc therm %09
Dump Request !
OS shutdown Alm
Power On Cnt Alm
240VA Power Down
Power Unit 1 Alm
Power Unit 2 Alm
Proc Missing
Proc T-Trip
Processor IERR
SMI timeout
WDT timeout
CPU Fan Alarm
Front Fan Alarm
Rear Fan Alarm
PCI Fan Alarm
HDD Fault
Description
A low temperature warning is detected.
A low temperature alarm is detected.
A high temperature warning is detected.
A high temperature alarm is detected.
A low temperature warning in processor is
detected.
A low temperature alarm in processor is
detected.
A high temperature warning in processor
is detected.
A high temperature alarm in processor is
detected.
A high temperature warning in processor
1 is detected.
A high temperature alarm in processor 1
is detected.
Dump switch is pressed.
OS stop error occurred.
Power supply failure occurred.
Power supply unit 1 failure occurred.
Power supply unit 2 failure occurred.
Processor is not found.
Thermal Trip occurred on processor. The
system is forcibly turned off.
IERR occurred on processor.
SMI timeout occurred.
Watchdog timer timeout error occurred.
A fan alarm occurred.
A hard disk drive error occurred.
Troubleshooting 8-25
Action
Fan may be faulty or clogged
with dust.
Contact your service
representative.
Wait for completion of
memory dump collection.
Take note of on-screen
message, wait for completion
of memory dump collection,
then contact your service
representative.
Contact your service
representative.
Check if power cord is
connected properly. If the
same error persists, contact
your service representative.
Contact your service
representative.
Contact your service
representative.
Fan may be faulty or clogged
with dust.
Contact your service
representative.
1. Check if the hard disk
drives are properly
installed.
2. Replace the failed hard
disk drive and perform
rebuilding.
3. If the same error occurs,
contact your service
representative.