" Malfunction of Swing Flap Motor (M1S)
A7
Remote
Controller
Display
Applicable
FXFQ, FXHQ, FXAQ
Models
Method of
Utilizes ON/OFF of the limit switch when the motor turns
Malfunction
Detection
Malfunction
When ON/OFF of the micro-switch for positioning cannot be reversed even though the swing flap
Decision
motor is energized for a specified amount of time (about 30 seconds)
Conditions
 Defect of swing motor
Supposed
 Defect of connection cable (power supply and limit switch)
Causes
 Defect of airflow direction adjusting flap-cam
 Defect of indoor unit PCB
Troubleshooting