60 hz.
Hide thumbs
Specifications
Ceiling Mounted Duct Type
Model
1, 3 Cooling Capacity
2, 3 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows×Stages×FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Airflow Rate (HH/H/L)
External Static Pressure
4
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight (Mass)
Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
 1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (27°CDB), 67°FWB (19.4°CWB)
Standard external static pressure
Outdoor temperature: 95°FDB (35°CDB)
Equivalent ref. piping length: 25ft (7.5 m), (Horizontal)
 2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21°CDB).
Standard external static pressure
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6°FWB)
Equivalent ref. piping length: 25ft (7.5 m), (Horizontal)
 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
 4 External static pressure is changeable in 7 (FXMQ07, 09, 12PVJU), 14 (FXMQ18, 24, 30, 36, 48PVJU) stages within the ( )
range by remote controller.
 5 Air filter is not standard accessory, but please mount it in the duct system of the suction side.
Select its colorimetric method (gravity method) 50% or more.
12
FXMQ07PVJU
Btu/h
7,500
Btu/h
8,500
Galvanized Steel Plate
11-13/16 × 21-5/8 × 27-9/16
in. (mm)
(300 x 549 x 700)
3×16×15
ft²(m²)
1.05 (0.32)
Sirocco Fan
HPkw
0.09
cfm
317/264/229
"Wg
0.4-0.12
Direct Drive
Microprocessor Thermostat for Cooling
and Heating
Glass Fiber
5
φ1/4 (6.4)(Flare Connection)
in. (mm)
φ1/2 (12.7)(Flare Connection)
in. (mm)
VP25
in. (mm)
(
External Dia. 1-1/4(31.8)
Internal Dia. 1(25.4)
Lbs (kg)
55 (25)
dBA
45/41
Fuse,
Fan Driver Overload Protector
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Drain Hose, Sealing Pads, Clamp Metal,
Air Discharge Flange, Air Suction
Flange
FXMQ09PVJU
9,500
10,500
Galvanized Steel Plate
11-13/16 × 21-5/8 × 27-9/16
(300 x 549 x 700)
3×16×15
1.05 (0.32)
Sirocco Fan
0.09
317/264/229
0.4-0.12
Direct Drive
Microprocessor Thermostat for Cooling
and Heating
Glass Fiber
5
φ1/4 (6.4) (Flare Connection)
φ1/2 (12.7) (Flare Connection)
VP25
)
(
External Dia. 1-1/4(31.8)
Internal Dia. 1(25.4)
55 (25)
45/41
Fuse,
Fan Driver Overload Protector
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Drain Hose, Sealing Pads, Clamp Metal,
Air Discharge Flange, Air Suction
Flange
3D066117B
SiUS34-907
FXMQ12PVJU
12,000
13,500
Galvanized Steel Plate
11-13/16 × 21-5/8 × 27-9/16
(300 x 549 x 700)
3×16×15
1.05 (0.32)
Sirocco Fan
0.09
335/282/246
0.4-0.12
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
5
φ1/4 (6.4)(Flare Connection)
φ1/2 (12.7) (Flare Connection)
VP25
)
(
External Dia. 1-1/4(31.8)
Internal Dia. 1(25.4)
55 (25)
48/45
Fuse,
Fan Driver Overload Protector
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Sealing Pads,
Clamp Metal, Air Discharge Flange,
Air Suction Flange
Specifications
)

   Related Manuals for Daikin VRV III-S RXYMQ36 48PVJU

This manual also for:

R-410a

Comments to this Manuals

Symbols: 0
Latest comments:
  • cp shukla Feb 16, 2016 06:50:
    RXYQ18PAY6 service manual & vrv Fulform