Oce XDL Reference Manual page 73

Lcds-module xdl/djde
Table of Contents

Advertisement

Print Processing
Parameter
CONSTANT=
sc
FONT=
value
INK=
value
LINE=
{n | (n,m) | (n,-)}
POSITION=
n
A29247-X4-X-8-7672
Definition(s)
sc
Represents the string constant to be printed for defi-
nition of string constants). The width of the copy mod-
ification rectangle is determined by the number of
characters specified by sc. More than one sc is al-
lowed.
There is no default.
value
May range from 1 to n, where n is the number of dif-
ferent fonts specified by the FONTS parameter of the
PDE command. A value of 1 specifies the first font in
the FONTS parameter, 2 the second, and so forth.
There is no default.
value
May range from 1 to n, where n is the number of dif-
ferent inks specified by the ILIST parameter of the
IDR command. A value of 1 specifies the first ink in
the ILIST parameter, 2 the second, and so forth.
The default 0 may also be specified, it instructs the
system to use the original ink, that is the ink used in
the report prior to that modified by the CME.
Only a reference to a primary colour is allowed.
This option has the following components:
n
The initial line number of the copy modification rect-
angle
m
The number of lines to repeat the information. If not
specified, the information applies only to the starting
line.
-
A dash character indicates that information is to ap-
ply to all lines on a page beginning with the line indi-
cated by n.
There is no default.
n
An integer value between 1 (the first position of the
print line) and the value specified by the length right-
part of the DATA= parameter in the LINE command.
The default is 1.
Summary of ac:CME Command Parameters
Offline
Online
DJDE
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
Y
Y
N
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

DjdePrismaproduction server v3.10

Table of Contents