No reinforcement strips on the output without an error
message
Introduction
This error occurs when there are no reinforcement strips on the output although reinforce-
ment is selected. This can happen when the file header (Remote Control Format or Océ
Job Ticket) contains instructions to have no reinforcement.
Note:
If you want to process A4 formats, reinforcement can be disabled for this format.
How to solve this error
Press the Stop key on the operator panel twice.
1.
Open the side door of the reinforcement unit.
2.
Check if there are loose reinforcement strips in the unit with the protection sheet still
3.
on.
A
[254] Situation A: No mechanical error Situation B: Mechanical error
If yes, remove the tape strips in the reinforcement unit. If the protection sheet is not on
4.
the reinforcement strip (see situation A), there is no mechanical error and you should
insert a new tape roll as described in
If this error frequently occurs, call the Océ service organization (see
page
327).

No reinforcement strips on the output without an error message

B
'Insert a new tape roll' on page
278.