No reinforcement strips on the output

No reinforcement strips on the output
Introduction
When there is no reinforcement strip on the output, then
• The reinforcement strip is not correctly installed, or
• The reinforcement strip is not available.
Procedure
1.
Press the Online key on the operator panel to put the printer offline.
2.
Open the side door of the reinforcement unit.
3.
Check for loose reinforcement strips in the unit with the protection sheet on (see situation B in the
figure).
[140] Situation A: No mechanical error. Situation B: Mechanical error.
4.
If there are, remove the tape strips in the reinforcement unit.
[141] Removing the tape
NOTE
If the protection sheet is not on the reinforcement strip, there is no mechanical error. You must
insert a new tape roll
call your Océ representative.
5.
Remove all tape between the rollers and the knives.
6.
Install a new trailing strip of tape between the rollers and the knives.
282
Chapter 7 - Maintain and troubleshoot the Océ PlotWave 750 system
Insert a new tape roll on page
272. If this error occurs frequently, you must