Scanning originals with filing strip
Select one of the roll selection keys on the operator panel.
1.
Select the 100% key.
2.
Make sure that 'auto zoom', 'auto roll', and 'scan width' are not selected.
3.
Make other settings as required.
4.
Feed the original.
5.
Leading and trailing strip
It is possible to adjust the length of both the leading and trailing strips to eliminate or
1.
add a filing strip. Leading and trailing strips can be extended up to 400 mm or shortened
up to 400 mm (15.7 inches).
Copy with removed filing strips along the leading and trailing strip
Open the "Sheet" card in the "Original" section.
1.
Press the "Remove strip" function key.
2.
[141] Remove strip
Adjust the values for the trailing strip using the numeric or arrow keys.
3.
Press the "Remove strip" function key again.
4.
Adjust the values for the leading strip using the numeric or arrow keys.
5.
Make other settings as required.
6.
Feed the original.
7.