CAN/LIN Triggering and Serial Decode
Example: If a data frame contains an active error flag, both the FRAMES
counter and the ERR counter will be incremented. If a data frame
contains an error that is not an active error it is considered a partial
frame and no counters are incremented.

Interpreting CAN Lister Data

In addition to the standard Time column, the CAN Lister contains these
columns:
• ID — frame ID.
• Type — frame type (RMT remote frame or Data).
• DLC — data length code.
• Data — data bytes.
• CRC — cyclic redundancy check.
• Errors — highlighted in red. Errors can be Acknowledge (Ack, A), Form
Aliased data is highlighted in pink. When this happens, decrease the
horizontal time/div setting and run again.
358
(Fo), or Frame (Fr). Different kinds of errors can be combined like
"Fo,Fr" in the above example.