6.4. OK Mode

6.4.
OK Mode
6.4.
6.4.
OK Mode
OK Mode
The procedure of OK mode is as follows:
1 Put the article on the stopped weighing conveyor.
2 Pack the elements into the article by hand.
3 Press the START key. When the weighing value is OK, the article can be moved out.
The mode can be used with the buzzer according to the preset parameters.
In the stop mode, the current weighing value and the comparison display is always
updated. The comparison output is turned off. The buzzer and the comparison display
are turned off when the weighing value is within the zero band.
In the beginning of the operation mode, the display is reset and the buzzer becomes silent.
Eval delay timer
When
When the result is OK, the preset OK terminal is turned on.
When judgement is achieved, the weighing value and the comparison result are held,
the conveyor output is turned on and the article is moved out.
When C
onveyor stop delay timer
comparison output and conveyor output are turned off.
When the result is not OK, the comparison is achieved and the display is held until
C
onveyor stop delay timer
The mode does not use any selector.
Caution
The buzzer is used for hand operation support with the following AND condition.
1 While stopping conveyor.
2 Gross value is not within zero band.
Buzzer condition 1
Buzzer condition 1
3
Buzzer condition 1
Buzzer condition 1
already preset.
Concerning Principal Items
Address
Parameter
5q f- 1
3
5q f- 2
1
5q f-29
2
5q f- 6
01000000
5q f- 8
00100000
5q f-10
00010000
5q f-41
500
5q f-59
5qf-43
[
(Including Parameter Example)
Address name
Parameter name
Weighing mode
OK mode
Selection of comparison
3 levels with target
Detector
Tail edge
Buzzer condition 2
Buzzer condition 4
Buzzer condition 6
Buzzer ON timer
Conveyor stop delay timer
] is up, averaging and judgement is performed.
5qf-59
[
5qf-59
[
] is up.
5qf- - - - 5 5 5 5 ] to
5qf
5qf
Buzzer condition 6
Buzzer condition 6
[5qf
Buzzer condition 6
Buzzer condition 6
Setpoints and comparison method
Target, Lo (light), Hi(heavy)
Detection method
Position sensor detects the end of an article.
Buzzer sounds at Lo. Interval is 0.5Hz.
1: buzzer sounds, 0: no buzzer
Buzzer sounds at OK. Interval is 2Hz.
1: buzzer sounds, 0: no buzzer
Buzzer sounds at Hi. Interval is 8Hz.
1: buzzer sounds, 0: no buzzer
Range is 0.00 to 99.99 sec.
5.00 seconds
The delay timer of conveyor after judgement.
Range is 0.00 to 99.99 sec.
Page 33
] is up, the hold display is canceled,
Description
5qf- - - - 10
5qf
5qf
10] are
10
10