AND Check Weighing Indicator AD-4404 Instruction Manual page 146

Check weighing indicator
Table of Contents

Advertisement

Category address: [Function] - [Set Function] - [Serial] - [RS-485]
Category
address
symbol
r5 f- 1
Output data
Communication
r5 f- 2
mode
r5 f- 3
Baud rate
r5 f- 4
Parity check
Character
r5 f- 5
length
r5 f- 6
Stop bits
r5 f- 7
Terminator
r5 f- 8
Address
Response
r5 f- 9
timer
r5 f- 10
Do not change. Internal reservation.
r5 f- 11
Name
When jet stream mode of [r5 f- 2] is
used, 1, 2 or 3 can be selected. When
the display value is held in jet stream
mode, output is not stopped.
1: Displayed value
2: Gross value
3: Net value
4: Tare value
5: Gross value/ Net value/ Tare value
6: Displayed value with code
7: Gross value with code
8: Net value with code
9: Tare value with code
10: Gross value/ Net value/ Tare value
with code
1: Stream mode
2: Auto print mode
3: Manual print mode
4: Jet stream mode
5: Command mode
6: MODBUS
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps (Jet stream mode only)
0: Not used
1: Odd
2: Even
7: 7 bits
8: 8 bits
1: 1 bit
2: 2:bits
1: CR
2: CR LF
0:
1 to 99: Address used
Set the waiting timer from receiving
command to transmitting a response.
Descriptions
CR: 0Dh
LF: 0Ah
Address not used
Page 144
Range
and
Default
choices
1 to 10
1
1 to 6
6
1 to 7
5
0 to 2
0
7, 8
8
1 to 2
1
1 to 2
2
0 to 99
0
0.0 to
0.0 s
25.5 s
AD-4404