6-3 CALF-14="1" Weighing Mode
(Normal batching in customer programmed control mode)
Output signal
Zero band
Full-flow
medium-flow
Dribble-flow
Over limit
Under limit
• When an output condition is established, a relevant output terminal is turned on (power continuity with output COM).
• An output terminal number can be selected with OUTF-01 through OUTF-08. See {Appendix C: Function List}
• A set point signal output is turned off unconditionally when the operation mode is other than the normal mode.
Weighing process
*
Programming with a PLC (Programmable Logic Controller) is required for this weighing mode.
Sequence #
1
2
3
4
5
Final - Optional preliminary ≤
Final -
Preliminary
Final -
Free fall
Final +
Over limit
• The "Tare" signal is input.
• The display shows "0".
• Gates G1 (full-flow), G2 (medium-flow), and G3 (dribble-flow) open.
• The weight on the display is incremented, and reaches the weight of "Final –
Optional preliminary".
• The "Optional preliminary" output is turned ON.
• Gate G1 closes.
• The display shows the weight of "Final – Preliminary".
• The "Preliminary" output is turned ON.
• Gate G2 closes.
• The display shows the weight of "Final – Free fall".
• The "Final" output is turned ON.
• Gate G3 closes.
• Weighing completes at a stable display.
*
The display shows the final weight, indicating that hopper 2 has been filled to
that weight. Use the over limit/under limit setting to check whether the
weighing value is within limits.
• Gate G4 (Discharging gate) opens to discharge and fill the container.
*
The use of the zero range setting can check if the ingredient has been
completely discharged.
Output condition
Gross weight ≤ Zero band
Net weight
≤
Net weight
≤
Net weight
<
Net weight
Net weight
Process
6-4
<
Final
- Under limit
Need help?