AND Check Weighing Indicator AD-4404 Instruction Manual page 141

Check weighing indicator
Table of Contents

Advertisement

Category address: [Function] - [Set Function] - [Sequence] - [Zero track]
Parameters for Dynamic Zero Tracking Function
Category
address
symbol
Zero tracking
5q f-71
back timer
Tracking
5q f-72
average timer
Tracking MIN
5q f-73
interval
Tracking
5q f-74
amplitude
Refer to "8.1.2. Dynamic Zero Tracking Function".
s : second,
5q f-72, Zero tracking average timer
It is time to perform zero tacking.
Gross
0
Position sensor
5q f-42
Chattering timer
5q f-43
Eval delay timer
5q f-72
Zero tracking average timer
5q f-73
Zero tracking MIN interval
AD-4404
Name
The time to stop zero tacking before
weighing the article.
Average time.
Minimum interval between weighings.
If next weighing performs before the
timer is up, zero tracking is not
performed.
Tolerance value to perform zero tacking.
If absolute average value of zero
tracking is above this parameter, zero
tracking is not performed.
d: digit
5q f-71, Zero tacking back timer
It is time to stop zero tacking before
weighing the article.
Zero tracking is calculated at this time
Descriptions
5q f-72,
Zero tracking average timer
Detection
Judgement
Page 139
Range
and
choices
0.0 to
5.0 s
0.0 to
5.0 s
0.0 to
99.9 s
0.0 to
99.9 d
5q f-74,
Zero tracking amplitude
Detection
Judgement
5q f-73, Zero tracking MIN interval
If the article is detects within time of
5q f-73, zero tracking is not
attained.
Default
1.0 s
1.0 s
10.0 s
0.0 d