AND Check Weighing Indicator AD-4404 Instruction Manual page 151

Check weighing indicator
Table of Contents

Advertisement

Category address: [Function] - [Set Function] - [Option] - [slot n] - [OP-03] or
Category address: [Function] - [Set Function] - [Option] - [slot n] - [OP-04]
OP-04: Option RS-232C Interface
OP-03: Option RS-422 / RS-485 Interface
Category
address
symbol
03 f- 1
Output data
04 f- 1
03 f- 2
Communication
04 f- 2
mode
03 f- 3
Baud rate
04 f- 3
03 f- 4
Parity check
04 f- 4
03 f- 5
Charactor
04 f- 5
length
03 f- 6
Stop bits
04 f- 6
03 f- 7
Terminator
04 f- 7
03 f- 8
Address
04 f- 8
AD-4404
Name
When jet stream mode of [r5 f- 2] is
used, 1, 2 or 3 can be selected. When
the diplay value is held in jet stream
mode, output is not stoped.
1: Displayed value
2: Gross value
3: Net value
4: Tare value
5: Gross value/ Net value/ Tare value
6: Displayed value with code
7: Gross value with code
8: Net value with code
9: Tare value with code
10: Gross value/ Net value/ Tare value
with code
1: Stream mode
2: Auto print mode
3: Manual print mode
4: Jet stream mode
5: Command mode
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps (Jet stream mode only)
0: Not used
1: Odd
2: Even
7: 7 bits
8: 8 bits
1: 1 bit
2: 2:bits
1: CR
2: CR LF
0:
1 to 99: Address is used
Descriptions
CR: 0Dh
LF: 0Ah
Address is not used
Page 149
slot n : slot number
Range
and
Default
choices
1 to 10
1
1 to 5
5
1 to 7
5
0 to 2
0
7, 8
8
1 to 2
1
1 to 2
2
0 to 99
0

Advertisement

Table of Contents
loading

Table of Contents