RS-485 2 Wire Connections for Command Mode
Settings
RS-485
Host computer
AD-4402
No.1
AD-4402
No.32
Turn on
terminator switch
Caution
This connection can be used only with command mode.

Settings of Parameters

Refer to "11. Function List".
Timing Chart
Keep the delay time above 4 ms between the last response and the next command.
Set response time (tr).
Use a long delay time, when there is noise.
Use 4 ms or more from the output finish to receiveing the next command
Hi-Z: Hi impedance
Waiting time from command to
response: tr. Set tr at [ 03 f- 9 ].
Hi-Z
Host computer
AD-4404
Address 1
AD-4404
Address 2
AD-4404
Terminator resistor
100 ~ 120
A
B
FG
TERMINATOR
ON
OFF
OFF
OFF
OFF
SDA
SDB
RDA
RDB
SG
FG
TERMINATOR
ON
ON
ON
ON
OFF
SDA
SDB
RDA
RDB
SG
FG
[03 f- 9] < tr < [03 f- 9] + 50 ms
C
L
@01RW
R
F
Hi-Z
@01ST,NT,+0123.45kg
[03 f-11] [2]
1/2W
The host computer may have
inverse polarity terminals.
2 (SDA) and 3 (SDB)
connect nothing.
Use twisted-pair wire.
Use shield cable, if necessary.
Connect a terminator
resistor at the indicator that
is farthest from the host
computer.
Waiting time until next
command: td > 4 ms
Hi-Z
C
L
R
F
Hi-Z
Page 109
The host computer may include
the terminator resistor.
Waiting time from
command to response: tr.
Set tr at [ 03 f- 9 ].
C
L
@02RW
R
F
Hi-Z
@02ST,NT,+0123.45kg