HP D2D configuration problems

I cannot see a newly created device

When you create a new device on the HP D2D Backup System, the host will not be able to see the device
until you connect manually to it using the iSCSI Initiator. See
for more information. If you still cannot see the device, check Device Manager to make sure it is
visible from the host.

I cannot see additional slots from the backup application

When you create additional slots for an autoloader/library on the HP D2D Backup System, you may
need to restart services on the backup application so that it can see the new slots.

Upgrade licenses

Can I transfer the License To Use to a different HP D2D?

No. The LTU is tied uniquely to the serial number of your HP D2D hardware. If your hardware serial
number changes (by swapping out the unit motherboard), the LTU must be transferred to the new
hardware via the HP Licensing website. A new LTU is generated, which must then be applied and
activated via the Web Management Interface on the repaired/replaced system.

More disks present than are licensed

If the Disk Licensing status on the Summary page states that more disks are present than are licensed, you
need to obtain and apply a License To Use key. See

Replacement of hardware

In the unlikely event that replacement hardware is required to be installed, please consult the Maintenance
and Service Guide on http://www.hp.com/support.

Event log displays 'Invalid BIOS Assembly name'

This event log entry and email alert will occur if a motherboard has been replaced on your HP D2D.
This is a warning message, designed for future expansion of the system. Your HP D2D will operate fully
without impacting anything. This message will occur each time you restart your HP D2D system.

RAID battery backup status

If the RAID battery fails

The RAID battery normally has a status of OK, which means that is fully charged or in the process of
recharging. (It is normal for the battery to recharge, if the HP D2D has been powered off for more than
24 hours.) If the RAID battery status shows as failed on the Summary or RAID page, it must be replaced.
"The Microsoft iSCSI
"License
(Settings)" on page 90.
D2D Backup SystemHP D2D4004 and HP D2D4009
Initiator" on page 51
121

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks D2D100 - Backup System and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Storageworks d2d4004Storageworks d2d4009

Table of Contents