4
Switch View
Thresholds for the Environmental Classes
The Environmental classes are displayed by selecting the Environmental file from the separate
column left of the Configure Thresholds tab.
The columns for the Temperature, RX Power, TX Power and current areas contain the following
items:
Threshold Type
drop-down list
High/Low
drop-down list
Area Select
checkbox
Thresh element
drop-down list
The column for the Power Supply area contain the following item:
"Send alarms
when" box
Thresholds for the GBIC Classes
The GBIC classes are displayed by selecting the GBIC file from the separate column left of the
Configure Thresholds tab.
The columns for the Temperature, RX Power, TX Power and current areas contain the following
items:
Threshold Type
drop-down list
High/Low
drop-down list
Scale
Area Select
checkbox
Thresh element
drop-down list
The column for the Current area contain the following item:
"Send alarms
when" box
4-12
Select the threshold type (exceeded, above, in-between, below,
changed).
Select to enter the high and low settings for the threshold type
selected in the Threshold Type drop-down list (not available for all
areas).
Select a Fabric Watch area to configure. Only one area can be
selected at a time.
Check or uncheck to specify if you want this element to be
monitored.
Use this text box to specify whether you want to be notified when the
area is in the acceptable range (OK) or is faulty (FAULTY).
Select the threshold type (exceeded, above, in-between, below,
changed).
Select to enter the high and low settings for the threshold type
selected in the Threshold Type drop-down list (not available for all
areas).
Specify the point at which you want to set the specified threshold.
Select a Fabric Watch area to configure. Only one area can be
selected at a time.
Check or uncheck to specify if you want this element to be
monitored.
Use this text box to specify whether you want to be notified when the
area is in the acceptable range (OK) or is faulty (FAULTY).