2. Rotate the other hinge pin on the front adapter-retention bracket into position and push the hinge pin into
the other metal hinge point. The hinge pin will protrude through the hole in the metal hinge point when
the adapter-retention bracket is seated correctly.
3. Reinstall any adapters that you removed earlier.
4. Close the front and rear adapter retention brackets.
5. Go to "Completing the FRU replacement" on page 200.

Replacing the hot-swap power supply cage

Use the following procedures to replace the power supply cage. This procedure applies only to server
models that have a hot-swap power supply.

Removing the hot-swap power supply cage

To remove the power supply cage, complete the following steps:
1. Read the safety information that begins on page "Important Safety Information" on page 1.
2. Turn off the server and all attached devices; then, disconnect all power cords and external cables.
3. Unlock and remove the side cover (see "Removing the side cover" on page 142).
4. Remove the hot-swap power supplies (see "Replacing a non-hot-swap power supply" on page 190).
Note: It might be helpful to lay the server on its side for the remainder of this procedure.
5. Disconnect the cables from the power supply cage to the system board and all internal components.
6. Remove the four black screws that secure the power supply cage to the chassis; then, slide the cage
toward the front of the server to disengage the retaining clips
the cage out of the chassis.
7. If you are instructed to return the power supply cage, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.

Installing the hot-swap power supply cage

This procedure applies only to server models that have hot-swap power supply.
To install the hot-swap power supply cage, complete the following steps: