Replacing The Sas/Sata Hard Disk Drive Backplane - Lenovo ThinkServer TS200 Hardware Maintenance Manual

Hardware maintenance manual for ts200
Table of Contents

Advertisement

To install the simple-swap backplate, complete the following steps.
1. Position the bottom edge of the simple-swap backplate on the lower lip of the drive cage.
1
Retaining tab
2
Drive cage release tab
3
Locating pins
4
Simple-swap backplate
5
Retaining latch
2. Tilt the top of the simple-swap backplate toward the drive cage and over the locating pins until the
retaining latch is engaged securely.
3. Press and hold the retaining tab on top of the cage; then, rotate the drive cage into the chassis until it
locks into place.
4. Connect the signal cables to the system board (see "System-board internal connectors" on page 131 for
the location of the Serial ATA drive connectors).
5. Connect the power cables to the simple-swap backplate.
6. Install the hard disk drive fan assembly on the hard disk drive cage (see "Replacing the hard disk drive
fan assembly" on page 175).
7. Install the simple-swap hard disk drives that you removed from the hard disk drive cage (see "Installing a
simple-swap hard disk drive" on page 160).
8. Go to "Completing the FRU replacement" on page 200.

Replacing the SAS/SATA hard disk drive backplane

Use these procedures to replace he SAS/SATA hard disk drive backplane. These procedures apply only
to hot-swap server models with a SAS/SATA hard disk drive backplane installed on the back of the hard
disk drive cage.