• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530" on page 209
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
0011004
Microprocessor failed BIST.
001100A
Microcode updated failed.
0050001
DIMM disabled.
0051003
Uncorrectable DIMM error
0051006
DIMM mismatch detected
0051009
No memory detected.
Action
1. Update the server firmware to the latest level (see
"Updating the firmware" on page 269).
2. (Trained service technician only) Reseat
microprocessor.
3. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
1. Update the server firmware to the latest level (see
"Updating the firmware" on page 269).
2. (Trained service technician only) Replace the
microprocessor.
1. If the server fails the POST memory test, reseat the
DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit (see "Replacing a
memory module" on page 147).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA Preboot memory test (see "Running
the diagnostic programs" on page 67).
1. If the server failed the POST memory test, reseat
the DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit see "Replacing a memory
module" on page 147 ).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA Preboot memory test (see "Running
the diagnostic programs" on page 67).
Make sure that the DIMMs match and are installed
in the correct sequence (see "Replacing a memory
module" on page 147).
1. Make sure that the server contains DIMMs.
2. Reseat the DIMMs.
3. Install DIMMs in the correct sequence (see
"Replacing a memory module" on page 147).