• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• SeeChapter 7 "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530" on page 209
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
The Processor CPU nStatus has
Failed with IERR.(n = microprocessor
number)
An Over-Temperature Condition has
been detected on the Processor
CPU nStatus.(n = microprocessor
number)
Error
A processor failed - IERR
condition has occurred.
Error
An overtemperature
condition has occurred
for microprocessor n.(n =
microprocessor number)
1. Make sure that the latest levels
of firmware and device drivers
are installed for all adapters
and standard devices, such as
Ethernet, SCSI, and SAS.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Run the DSA program for the
hard disk drives and other I/O
devices.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat sink for
microprocessor n is installed
correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
.