• Some server models come with a ServeRAID-BR10il v2 SAS/SATA RAID controller installed. The
ServeRAID-BR10il v2 controller enables integrated RAID levels-0 and level-1.
• You can install full-length adapters that are included in the supported options list in slots 1 through 5
(depending on your model).
• The 32-bit slots 4 and 5 support 5.0 V keyed PCI adapters; they do not support 3.3 V keyed adapters.
Universal adapters are supported in slots 4 and 5 if they are universally keyed.
• The server scans PCI Express Gen 2 x8 (x8) slot 1, PCI Express Gen 2 x8 (x8) slot 2, PCI Express Gen 2
x4 (x4) slot 3, and PCI slots 4 and 5 to assign system resources. Then, the server starts the PCI devices in
the following order, if you have not changed the default startup sequence: PCI Express Gen 2 x8 (x8) slot
1, PCI Express Gen 2 x8 (x8) slot 2, PCI Express Gen 2 x4 (x4) slot 3, PCI slot 4, and PCI slot 5.
• See http://www.lenovo.com/thinkserver and click the Options tab for a list of supported options.
To install an adapter, complete the following steps.
Note: Static electricity that is released to internal server components when the server is powered-on might
cause the server to stop, which might result in the loss of data. To avoid this potential problem, always use
an electrostatic-discharge wrist strap or other grounding system when you work inside the server with the
power on.
To install an adapter, complete the following steps:
1. Read the safety information that begins on page "Important Safety Information" on page 1.
2. Turn off the server and peripheral devices and disconnect all external cables and power cords; then,
remove the side cover. See "Removing the side cover" on page 142.
3. Follow the cabling instructions, if any, that come with the adapter. Route the adapter cables before
you install the adapter.
4. Follow the instructions that come with the adapter to set jumpers or switches, if any.
5. Rotate the rear adapter-retention bracket to the open position and remove it from the server.
6. Remove the screw that secures the expansion-slot cover to the chassis. Store the expansion-slot cover
and screw in a safe place for future use.
Note: Expansion-slot covers must be installed on all vacant slots. This maintains the electronic emissions
standards of the server and ensures proper ventilation of server components.