Lenovo ThinkServer TS200 Hardware Maintenance Manual page 214

Hardware maintenance manual for ts200
Table of Contents

Advertisement

• For Windows based operating systems:
– ibm_rndis_server_os.inf
– device.cat
• For Linux based operating systems:
– cdc_interface.sh
4. After you install ASU, Type the following commands to set the DMI:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]asu
set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]asu set
SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
<s/n>
<asset_method>
[access_method]
• Online authenticated LAN access, type the command: [host <imm_internal_ip>] [user
<imm_user_id>][password <imm_password>]
Where:
imm_internal_ip
imm_user_id
imm_password
Note: If you do not specify any of these parameters, ASU will use the default values. When the default
values are used and ASU is unable to access the IMM using the online authenticated LAN access
method, ASU will automatically use the following unauthenticated KCS access method.
The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoProdName <m/t_model>
user <imm_user_id> password <imm_password>asu set SYSTEM_PROD_DATA.SYsInfoSerialNum <s/n> user <imm_user_id>
password <imm_password>asu set SYSTEM_PROD_DATA.SYsEncloseAssetTag <asset_tag>
user <imm_user_id> password <imm_password>
Examples that do use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>asu set SYSTEM_PROD_DATA.SysInfoSerialNum
<s/n>asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a value for
access_method when you use this access method.
206
Hardware Maintenance Manual
The server machine type and model number. Type
mtm xxxxyy, where xxxx is the machine type and
yyy is the server model number.
The serial number on the server. Type sn zzzzzzz,
where zzzzzzz is the serial number.
The server asset tag number. Type asset
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset
tag number.
The access method that you select to use from
the following methods:
The IMM internal LAN/USB IP address. The
default value is 169.254.95.118.
The IMM account (1 of 12 accounts). The default
value is USERID.
The IMM account password (1 of 12 accounts).
The default value is PASSW0RD (with a zero 0
not an O).

Advertisement

Table of Contents
loading

Table of Contents