Lenovo ThinkServer TS200 Hardware Maintenance Manual page 124

Hardware maintenance manual for ts200
Table of Contents

Advertisement

Table 5. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530" on page 209
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
405-901-xxx Intel
Ethernet
Device
405-901-xxx Intel
Ethernet
Device
116
Hardware Maintenance Manual
State
Test Control
Failed
Registers
Test MII
Failed
Registers
Description
Action
1. Make sure that the component
firmware is at the latest level.
The installed firmware level is
shown in the DSA event log in
the Firmware/VPD section for this
component. For more information,
see "Updating the firmware" on
page 269.
2. Run the test again.
3. Replace the component that is
causing the error. If the error is
caused by an adapter, replace
the adapter. Check the PCI
Information and Network Settings
information in the DSA event log to
determine the physical location of
the failing component.
4. If the failure remains, go to
the Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
1. Make sure that the component
firmware is at the latest level.
The installed firmware level is
shown in the DSA event log in
the Firmware/VPD section for this
component. For more information,
see "Updating the firmware" on
page 269.
2. Run the test again.
3. Replace the component that is
causing the error. If the error is
caused by an adapter, replace
the adapter. Check the PCI
Information and Network Settings
information in the DSA event log to
determine the physical location of
the failing component.
4. If the failure remains, go to
the Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.

Advertisement

Table of Contents
loading

Table of Contents