Lenovo ThinkServer TS200 Hardware Maintenance Manual page 34

Hardware maintenance manual for ts200
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530" on page 209
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
2018002
Option ROM resource allocation failure
3xx0007 (xx
Firmware fault detected, system halted
can be 00 -
19)
3038003
Firmware corrupted
3048005
Booted secondary (backup) UEFI Image
26
Hardware Maintenance Manual
Action
Informational message that some devices might not
be initialized.
1. If possible, rearrange the order of the adapters
in the PCI slots to change the load order of the
optional-device ROM code.
2. Run the Setup utility, select Startup Options, and
change the boot priority to change the load order
of the optional-device ROM code.
3. Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a. Select Startup Options -> Planar Ethernet
(PXE/DHCP) to disable the integrated Ethernet
controller ROM.
b. Select Advanced Functions -> PCI Bus
Control -> PCI ROM Control Execution to
disable the ROM of the adapter in the PCI slots.
c. Select Devices and I/O Ports to disable any of
the integrated devices.
4. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Each adapter
b. (Trained service technician only) System board
1. Recover the server firmware to the latest level (see
"Updating the firmware" on page 269).
2. Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the default
values (see "System-board switches and jumpers"
on page 132.
3. Remove any recently installed hardware.
1. Run the Setup utility, select Load Default Settings,
and save the settings to recover the server
firmware.
2. (Trained service technician only) Replace the
system board.
Information only. The backup switch was used to boot
the secondary bank.

Advertisement

Table of Contents
loading

Table of Contents